05-15-96 79 26
8.1.6 Pause/pulse relay when emptying with air veyor
In those cases when emptying of the granule bin with an air veyor has been
chosen, the pause/pulse relay should be cancelled to prevent a glut in the
granule bin.
When delivered, the relay is preset
as follows:
T1 = range 1 - 10 m
T2 = range 6 - 60 s
where
Pause time T1 (the time the air
veyor is idle) is selected using
switches (A) and (B). Then the
time is set using the handwheel
T
off
= T
1
.
Delay time interval T2 (the time
the air veyor is working) is
selected using switches (C) and
(D). Then the time is set using the handwheel T
on
= T
2
.