Conair S900II System Instrukcja Użytkownika Strona 20

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 46
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 19
III – The axes’ parameters
S900–II CAN and AXES Configuration
Version 2.0 |–>
PARAMETER Abbreviation Description Parameter
value
Corresponding function
618
754
890
1026
1162
DINV_MAX_X
DINV_MAX__Y
DINV_MAX_Z
DINV_MAX_B
DINV_MAX_C
Maximum movement in the
opposite direction in
1/10 mm.
1 –> 300
Value of movement in the opposite direction to the command, beyond which the
fault “D_46: $ –MVT IN REVERSE DIRECTION is displayed.
Default value :
300
Possible value : 1 –> 300 Interaction with other parameters :
619
755
891
1027
1163
ATCP_FM_X
AT_CP_FM_Y
AT_CP_FM_Z
AT_CP_FM_B
AT_CP_FM_C
End of movement
anticipation value in
1/10 mm.
THIS PARAMETER IS ONLY
APPLICABLE FOR THE
BRAKED ASYNCHRONOUS
AXES.
0 –> 9999
Value defining the difference between the real programmed position and the ima-
ginary position aimed for by the movement manager. This parameter is used to
compensate, to a certain extent, the follow–up errors due to the motor sliding and
the behaviour of the speed driver.
Default value :
50
Possible value : 0 –> 9999 Interaction with other parameters :