5
Maintenance
Maintenance l 5-3
NOTE: Portable dewpoint moni-
tors purchased from Conair are
provided with a male connector
that plugs into the dewpoint
check port. If you purchased
your portable instrument else-
where, the male connector is
available through the Conair
parts department.
NOTE: The dewpoint check port
was not included on early
dryers. It can be added easily.
Contact the Conair parts
department or follow the
alternate procedure.
Replacement dewpoint
monitors, male connectors
and dewpoint check ports
are available from Conair.
Contact Conair Parts
(800) 458 1960
From outside of the
United States, call:
(814) 437 6861
Checking the Dewpoint
It is a good idea to monitor the dewpoint performance of your dryer periodically
with a calibrated portable dewpoint monitor, to ensure it is performing at
maximum capacity. Even if your dryer has a dewpoint readout, comparing it
to a portable instrument periodically will confirm that the dewpoint sensor and
readout is performing properly.
To check dewpoint:
1 Connect your portable dewpoint meter to the
dewpoint check port of the dryer.
2 Turn on the portable instrument, and ensure
there is positive airflow through the sensor.
3 Monitor the readout and allow ample time for it to stabilize before discon-
necting the portable dewpoint monitor. Some dewpoint monitors require a
substantial amount of time for residual moisture to be purged from the sensor.
4 In the event the dewpoint in not satisfactory, refer to the Troubleshooting
section of the manual, under A28 and P9 alarm for DC1.
Alternate Procedure: (for dryers with no dewpoint check port)
1 Stop dryer and allow it to cool.
2 Swing open or remove the left side panel. See Installation section entitled,
Opening the dryer doors (W1600-5000).
3 Remove the 1/8 inch NPT pipe plug at the process air outlet on the bottom
manifold of the desiccant wheel assembly.
4 Connect a portable dewpoint meter to the hole from which the plug was just
removed.